products

Earth Leakage BF62 RCCB RCD MCB Circuit Breaker

Basic Information
Place of Origin: CHINA
Brand Name: NBSE/OEM
Certification: CE,CB,
Model Number: BF62
Minimum Order Quantity: 100PCS
Price: Negotiable
Packaging Details: Export Carton
Delivery Time: 10-20days
Payment Terms: L/C, T/T, Western Union
Supply Ability: 30,000pcs per month
Detail Information
Poles Number: 2P,4P Rated Frequency: 50/60Hz
Rated Current: 6A-63A Leakage Action Current: 30mA,100mA,300mA
Standard: IEC61008-1 Warranty: 2 YEARS
Breaking Capability: 6KA Type: Electro-manetic Type,2PRCD
Rated Voltage: 230/240/400/415V Material: Copper,Silver Contact,Flame Resistant Plastic
High Light:

RCD MCB Circuit Breaker

,

RCCB MCB Circuit Breaker

,

RCD earth leakage circuit breaker


Product Description

BF62 RCCB RCD Mcb Circuit Breaker,Earth Leakage Circuit Breaker

 

BF02252003 RCCB RCD 2 Pole Type A Domestic Consumer Unit Circuit Breaker,Earth Leakage Circuit Breaker

 

1. APPLICATION

 

ID series residual current circuit breakers are applied to the lines with AC 50/60Hz,rated voltage of230V(1P+N) or 400V(3P+N),and rated current of 100A.In case of electric shock or electric leakage current exceeds the specified value, the residual current circuit breaker can switch off the fault circuit in a very short time, protecting the safety of person and electric equipment.

Can be used in the industrial, commercial, high-rise buildings, civil residences and other places.

    Main Features:
    Double pole RCCB circuit breakers in a range of current options
    Easily installed in your ESR modular consumer unit
    Safe and reliable product that is known to save lives and severely reduce risk of property damage

 

2. TECHNICAL PARAMETER

 

 

Technical Parameter
Spec Parameter
Rated Operating voltage(Ue)230V(1P+N)/400V(3P+N)
Rated Current(In)6,16,25,32,40,50,63A
Tripping TypeElectronic,Electromagnetic
CharacteristicA type, AC type, S type
Poles1P+N,3P+N
Rated Frequency50/60Hz
Rated Insulation voltage(Ui)500V
Rated residual current (IΔn)10,30,100,300mA
Rated residual switching on and800A
breaking capacity(IΔm)
Rated residual short-circuit current6000A
limit(IΔc)
Rated short-circuit current limit(Inc)6000A
Rated switching on and breaking capaity(Im)800A
Residual current tripping timet<0.1s
Rated impulse withstand voltage(Uimp)6kV
Electro-Mechanical life(times)>4,000 times
 
Standard Certificate
Comply with StandardIEC 61008-1
GB 16916
CertificateCE, CB, 


 

Working Envirnment
Humidity40℃ humidity notexceed 50% 20℃ humidity not exceed 90%
(Condensation on the product due to
changes in humidity has been considered)
Working Temperature-5℃~+40℃ and its average over aperiod of 24h does not exceed
Magnetic fieldNo more than 5 times the geomagnetic field
Pollution level2
Altitude(m)2000
 
Mounting and Wiring
Shock and vibrationShould be installed in the case of no obvious impact vibration
Installation category
Terminal connection typestype cable,type U bus, TH 35mm Din-rail
Wiring terminal connection conductor1.5~25 mm²
Wiring terminal copper size25 mm²
Tightening torque3.5N*m
Installation modeUsingTH35-7.5 profile installation, the title of
installation face and vertical face is not greater than5°
Wiring incoming modeupper and lower incoming is possible for ELM type,
only upper incoming for ELE type

 


3. OPERATION PRINCIPLE FIG.

Earth Leakage BF62 RCCB RCD MCB Circuit Breaker 0

 

 

4. WORKING PRINCIPLE

Earth Leakage BF62 RCCB RCD MCB Circuit Breaker 1

BF02252003 RCCB RCD 2 Pole Type A Domestic Consumer Unit Circuit Breaker
 A residual-current device (RCD), or residual-current circuit breaker (RCCB), is a device that quickly breaks an electrical circuit to prevent  serious harm from an ongoing electric shock. RCD Protection
 
· Line voltage independent RCCB for fault or additional protection with additional digital features
· System Monitoring: Preventive information / warning before the RCD trips in case of leakage currents: Integrated auxiliary contact(s), Local Indication
· New level of accuracy - Reduced unwanted tripping
· Local status indication of residual current through 3 LEDs
· No monthly test required
· Comprehensive range of accessories
· Real contact position indicator
· Fault current tripping indicator
· Automatic re-setting possible
· Transparent designation plate

 

FAQ:
Q1: What's your product Range?
A.
- Shell Unti-fire. nylon pa66 or not unti-fire.
- Parts, Copper or iron
- Point Sliver point or Copper point
 
Q2: Are you a manufacturer?
A. Yes, we are only produce the circuit breaker over 20 years from 1999.
 
Q3: Do you have stock products to sell?
A. No,we work on OEM orders, The means, material, quantity,packing solution,etc will depend on your requests.obviously, your logo can be printed on the products.
 
Q4. what's the payment term?
A. We accept TT,30% deposit and 70% balance agaisnt copy of BL
Q5. how's the delivery time ?
A. usually it will take about 30 days for 30000pcs
 
Q6. tell me the standard of package?
A. Normally are cartons, color box or white box
 
Q7. what kind of material of circuit breaker?
A. we have two types, one copper coil with silver point and the other is brass coil with copper point. It depends on your requirement. In fact, those two have no difference if normal work well. Only except the electrical life. Copper and silver is better and also higer price.
Q8. We want to know month capacity.
A. 400,000pcs/month
Q9. Where is your market?
A. Our products are popular in Western Europe, Middle-East, Afirca, South Asia ,South Ameirca countries and area. Some of them are our regular customers and some of them are developing. We hope you can join us and make mutural benifit from our cooperation.
Q10. what kind of certificate you have ?
A. CE, CB,CCC,ISO9000.
 
Q11. Do you inspect the finished products
A. Yes.Each step of products will be inpected by QC department before shipping.
 
Q12. How are you ship the finished products?
- By Sea
- By plane
- By counties,TNT, DHL,FEDEX,UPS.etc.

 

RCCB BF60 Specification.pdf
 

Contact Details
sales

Phone Number : +8613587466174

WhatsApp : +8613587466174